EasyManuals Logo

Midea MCA3U-09HRFN1-M(C) User Manual

Midea MCA3U-09HRFN1-M(C)
247 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
54
6.1.2 Micro-Switch Introduce:
MCA3U-09HRFN1-M(C), MCA3U-12HRFN1-M(C), MCA3U-18HRFN1-M(C),MCD-24HRFN1-M(C)
A. Micro-switch SW1 is for selection of indoor fan stop temperature (TEL0) when it is in anti-cold wind
action in heating mode.
Range: 24
o
C, 15
o
C, 8
o
C, according to EEROM setting (reserved for special customizing).
T2
Setting fan speed
H
M+
M
L
Super slow
Fan off
TEL0+16
TEL0+14
TEL0+12
TEL0+10
TEL0+8
TEL0+6
TEL0+12
TEL0+10
TEL0+8
TEL0+6
TEL0+4
TEL0
B. Micro-switch SW2 is for selection of indoor FAN ACTION if room temperature reaches the setpoint
and the compressor stops.
Range: OFF (in 127s), Keep running.
C. Micro-switch SW3 is for selection of auto-restart function.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea MCA3U-09HRFN1-M(C) and is the answer not in the manual?

Midea MCA3U-09HRFN1-M(C) Specifications

General IconGeneral
BrandMidea
ModelMCA3U-09HRFN1-M(C)
CategoryAir Conditioner
LanguageEnglish

Related product manuals