17.1 Indoor Unit Error Display
Operation
lamp
Timer lamp
Display
LED STATUS
1 time
X
E0
Indoor unit EEPROM parameter error
2 times
X
E1
Communication malfunction between indoor and
outdoor units
4 times
X
E3
Indoor fan speed malfunction
5 times
X
E4
Indoor room temperature sensor (T1 ) malfunction
6 times
X
E5
Evaporator coil temperature sensor (T2) malfunction
7 times
X
EC
Refrigerant leakage detection
8 times
X
EE
Water-level alarm malfunction
1 time
O
F0
Current overload protection
2 times
O
F1
Outdoor ambient temperature sensor (T4 ) malfunction
3 times
O
F2
Condenser coil temperature sensor (T3) malfunction
4 times
O
F3
Compressor discharge temperature sensor (T5)
malfunction
5 times
O
F4
Outdoor unit EEPROM parameter error
6 times
O
F5
Outdoor fan speed malfunction
8 times
O
F7
Communication malfunction between indoor unit and
auto-lifting panel
9 times
O
F8
Auto-lifting panel malfunction
10 times
O
F9
Auto-lifting panel malfunction is not closed
11 times
O
FA
Communication malfunction between indoor two
chips(For A6 Duct)
1 times
P0
Inverter module (IPM) malfunction
2 times
P1
Over-voltage or under-voltage protection
3 times
P2
Compressor top high temperature protection (OLP)/
High temperature protection of IPM board
4 times
P3
Low ambient temperature cut off in heating
5 times
P4
Compressor drive malfunction
6 times
P5
Indoor units mode conflict
7 times
P6
High pressure protection or low pressure protection (for
some models)
8 times
P7
Outdoor IPM temperature sensor error