60
MCD-36HRFN1-M(C), MCD-48HRFN1-M(D)
A. Micro-switch SW1 is for selection of indoor fan stop temperature (TEL0) when it is in anti-cold wind
action in heating mode.
Range: 24
o
C, 15
o
C, 8
o
C, according to EEROM setting (reserved for special customizing).
T2
Setting fan speed
H
M+
M
L
Super slow
Fan off
TEL0+16
TEL0+14
TEL0+12
TEL0+10
TEL0+8
TEL0+6
TEL0+12
TEL0+10
TEL0+8
TEL0+6
TEL0+4
TEL0
B.Micro-switch SW2 is for selection of indoor FAN ACTION if room temperature reaches the set point
and the compressor stops.
Range: OFF (in 127s), Keep running.
C.Micro-switch SW3 is for selection of auto-restart function.
Range: Active, inactive