5.7 E32 LED is lighting after the cycle finished.
The humidity sensor is blocked
by fluff
Clean or replace the humidity sensor
Replace the control panel
E32 LED is lighting after the cycle
finished.
Y
Y
N
5.8 E33 LED is lighting
The terminals of P3 are loosened
Plug in terminals
The terminals of front and rear NTC
are loosened
Plug in terminals
The terminals of front or rear NTC is
damaged检测技术参数
Replace NTC
The wire components are loosened or
damaged
Plug in or replace the wire assembly
Replace the control panel
E33 LED is lighting
Y
Y
N
Y
N
Y
N
Y
N
5 Troubleshooting