Specifications R410A Tropical Split Type Technical Manual
Floor-standing Type 60
2. Specifications
Model MFA-76CRN1 MFA-76HRN1 MFA-96CRN1 MFA-96HRN1
Power supply - 220~240V-1Ph-50Hz 220~240V-1Ph-50Hz
Temp. setting range
℃ ≥17 ≤30 ≥17 ≤30
Rated input power W 11700 11700 14400 14400
Rated current A 19.3 19.3 23.7 23.7
Cooling
Capacity
Btu/h
76000 76000 96000 96000
W 22000 22000 28000 28000
Input power W 7500 7500 9600 9600
EER W/W
2.93 2.93 2.92 2.92
Heating
Capacity
Btu/h
/ 78000 / 105000
W / 25000 / 31000
Input power W / 8300 / 10300
COP W/W
/ 3.01 / 3.01
Indoor air flow m
3
/h
4250 4250 5100 5100
Indoor noise level dB(A)
Type - R410A R410A
Control - Capillary Capillary
Fan
Type - Centrifugal fan Centrifugal fan Centrifugal fan Centrifugal fan
Dimension mm Φ250 Φ250 Φ250 Φ250
Drive type/ Motor step
- Direct/ Single Direct/ Single Direct/ Single Direct/ Single
Motor input * No. W 590 590 590 590
Motor speed rpm 870 870 870 870
Coil
Type - Copper tube and aluminum fin Copper tube and aluminum fin
Tube size mm Φ9.52 Φ9.52 Φ9.52 Φ9.52
No. of rows - 2 2 3 3
Fin per inch FPI 16 16 16 16
Length* height mm 982*715.5 982*715.5 983*715.5 983*715.5
Controller - Remote controller Remote controller
Drain pipe size mm 41 41 41 41
Dimension (W*H*D) mm 1200*1860*420 1200*1860*420
Packing (W*H*D) mm 1362*2023*582 1362*2023*582
Net/Gross weight kg 158/174 158/174 158/174 158/174
Shipping Qty per 20'/40'/40'HD pcs
15/32/32 15/32/32 15/32/32 15/32/32
Notes:
1. Nominal cooling capacities are based on the following conditions:
Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB; Equi valent ref. piping: 7.5m (horizontal)
2. Nominal heating capacities are based on the following conditions:
Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB; Equiv alent ref. piping: 7.5m (horizontal)