MCAC-UTSM-201406                       Midea R410A Full DC Inverter Split Type Series Technical Manual 
70 
Check whether the air inlet or outlet of the indoor unit and outdoor unit is blocked. 
Remove foreign substance if any. 
Check whether the ground wire is connected properly. 
Check whether the condensate water is discharged normally. 
Check whether the insulation work of refrigerant circuit and ventilating duct is on sound 
status. 
Check whether the installing seat is corroded or rusted. 
  Startup 
  Connect the indoor unit 12 hours after connect the outdoor unit to power supply. 
  Switch on the power control of remote controller or wired controller, and then startup 
the air conditioning. 
  Maintenance and upkeep of outdoor unit 
  The edge of some sheet metal assemblies and the fin of the condenser are very sharp. 
Incorrect operation may cause harm. Be cautious when cleaning them up. 
  Check the air inlet and outlet of the outdoor unit periodically to see whether they are 
blocked by stain or lampblack. 
  Only the professionals can perform repair. Before maintain the unit, turn off the main power 
switch. 
  Do not use water or air with a temperature higher than 50°C  to clean the panel. 
  Check  and  maintain the  ventilating  slot  once  every  half  years, wash  and  maintain  with 
corresponding disinfection shall process once. 
  Every two years are recommended. The filter can expel dust and other particles in the air. If 
it is blocked, the effect of the air conditioner will be degraded. Therefore, clean it every 
another two weeks if the air conditioner already has been used for a long period. If the 
indoor unit is installed in a place with heavy dust, clean the filter more often. 
  If the stain is heavy and difficult to clean, replace the filter. 
  Do  not  replace  the  power  cable  without  permission.  If  the  power  cable  is  damaged, 
specialized power cable must be used as substitute.