  Warning signals 
-  The warning signal is indicated by the LED display.   
-  The fault signal LED and the SSM relay do not respond. 
-  The pump continues to run with limited output.   
-  The indicated faulty operating status must not occur for a prolonged period. The cause must be eliminated. 
Figure 3-6.4: Warning signals 
Pump  hydraulics  have  fluid  running 
through them. 
Check the water volume/ pressure 
Sluggish  motor,  pump  is  operated 
outside of its specifications (e.g. high 
module  temperature).  The  speed  is 
lower than during normal operation. 
Check the ambient conditions 
*      In addition to the LED display, the fault signal LED is continuously illuminated in red. 
 
  In  order  to ensure the  service life of  the  pump,  it  is recommended  that  the  unit  run  at  least  once  every  2  weeks 
(ensure that the pump is running) or keep it powered on for a long time (in the power-on standby state, the unit will 
run the pump for 3 minutes every 6 hours)