EasyManua.ls Logo

Midea MHC - V18W/D2RN8 - Refrigerant Flow Diagrams

Midea MHC - V18W/D2RN8
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M thermal Mono
8 202005
Midea M thermal Mono Engineering Data Book
4.2 M thermal Leaving Water Temperature (LWT) Selection
The recommended design LTW ranges for different types of heat emitter are:
For floor heating: 30 to 35C
For fan coil units: 30 to 45C
For low temperature radiators: 40 to 50C
4.3 Optimizing System Design
To get the most comfort with the lowest energy consumption with M thermal, it is important to take account of the
following considerations:
Choose heat emitters that allow the heat pump system to operate at as low a hot water temperature as possible
whilst still providing sufficient heating.
Make sure the correct weather dependency curve is selected to match the installation environment (building
structure, climate) as well as ender users demands.
Connecting room thermostats (field supplied) to the hydronic system helps prevent excessive space heating by
stopping the outdoor unit and circulator pump when the room temperature is above the thermostat set point.
Midea CAC Confidential

Other manuals for Midea MHC - V18W/D2RN8

Related product manuals