M thermal Mono
202004 53
4.2 E0, E8 Troubleshooting
Digital display output
Description
Water flow failure.
E0 indicates E8 has displayed 3 times. When an E0 error occurs, a manual system restart is required before the system
can resume operation.
M thermal Mono stops running.
Error code is displayed on hydronic system main control board for refrigerant system and user interface.
Possible causes
The wire circuit is short connected or open.
Water flow rate is too low.
Water flow switch damaged.