M thermal Mono
202004 55
4.3 E1 Troubleshooting
Digital display output
Description
Phase sequence error.
Only applies to 3-phase models.
M thermal Mono stops running.
Error code is displayed on refrigerant system main control board for refrigerant system and user interface.
Possible causes
Power supply phases not connected in correct sequence.
Power supply terminals loose.
Power supply abnormal.
Main PCB damaged.