TS07: Indoor PCB / Display board communication error diagnosis and solution
Description: Indoor PCB does not receive feedback from the display board.
Recommended parts to prepare:
Communication wire
Indoor PCB
Display board
Troubleshooting and repair:
Is it still displaying the error code? The unit functions normally
Check the wirings and connections
Are all the connections
good?
Replace the indoor main PCB
Does the error still exist?
Replace the display board
Power off, then restart the unit 2 minutes
later
Ensure a proper connection
YES
NO
NO
YES