7. Capacity Tables
7.1 Cooling Capacity
MCA-12HRN1
Cooling Outdoor conditions (DB)
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC
21/15ºC DB/WB
TC 3.30 3.14 2.98 2.85
SC 2.44 2.41 2.38 2.39
Input 0.91 0.99 1.03 1.07
24/17ºC DB/WB
TC 3.39 3.23 3.07 2.88
SC 2.54 2.52 2.49 2.42
Input 0.97 1.03 1.08 1.13
27/19ºC DB/WB
TC 3.46 3.30 3.20 2.98
SC 2.56 2.54 2.50 2.44
Input 0.99 1.05 1.10 1.16
32/23ºC DB/WB
TC 3.52 3.39 3.33 3.07
SC 2.99 2.95 2.93 2.86
Input 1.03 1.08 1.16 1.20
MCA-18HRN1
Cooling Outdoor conditions (DB)
Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC
21/15ºC DB/WB
TC 5.46 5.19 4.93 4.72
SC 4.04 4.00 3.94 3.96
Input 1.58 1.71 1.79 1.84
24/17ºC DB/WB
TC 5.62 5.35 5.09 4.77
SC 4.21 4.18 4.12 4.01
Input 1.67 1.79 1.86 1.96
27/19ºC DB/WB
TC 5.72 5.46 5.30 4.93
SC 4.24 4.20 4.13 4.04
Input 1.71 1.81 1.90 2.00
32/23ºC DB/WB
TC 5.83 5.62 5.51 5.09
SC 4.96 4.89 4.85 4.73
Input 1.79 1.86 2.00 2.07