EasyManua.ls Logo

Midea MOV-120CN1-C

Midea MOV-120CN1-C
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R410A 50Hz Tropical Split AC MCAC-UTSM-2012-12
86
11.1 E1 malfunction
LED indicate E1
Fault of indoor temperature sensor T1
Judge 1: Whether the indoor temperature
sensor T1 is break off.
Yes
Connects it well.
No
Judge 2: Whether the indoor temperature
sensor T1 is malfunction.
Validate: Check whether the resistance of
the temperature sensor is correct
according to Annex 1.
Replace it.
No
Yes
Judge 3: PCB is malfunction
Replace indoor PCB