MCAC-UTSM-2014-03 R410A 380~415V 3Ph 50Hz TempMaker Series Split AC
0
Midea R410A T1 380V 50Hz 3Ph
Split Type TempMaker series
Technical Manual
Applicable Model:
Indoor unit Outdoor unit
MTB-76HWN1 MOV-76HN1-R
MTB-96HWN1 MOV-96HN1-R
MTB-120HWN1 MOV-120HN1-R
MHB-76HWN1 MOV-150HN1-R
MHB-96HWN1 MOV-192HN1-R
MHA-150HWN1
MHA-192HWN1
MFA2-76HRN1
MFA2-96HRN1
Midea reserves the right to discontinue, or change specification or designs at any time without notices and
without incurring obligations.
Библиотека СОК

Questions and Answers

  • A
    Amanda BeanAug 9, 2025
    Why is my Midea Air Conditioner cooling effect poor?
    • J
      Joseph ReidAug 9, 2025
      Several factors can cause a poor cooling effect. The condenser or evaporator may be dirty, requiring you to clean the heat exchanger. The filter might be blocked, so cleaning the filter is necessary. Ensure the intake or exhaust vents of the indoor and outdoor units aren't blocked by removing any obstructions to maintain ventilation. Closing any open windows and doors can help, as well as obstructing direct sunlight with curtains. Reducing heat sources in the room can also improve cooling. The refrigerant may be leaking or deficient, requiring leak detection and refilling the correct amount. Also, if the outdoor environment temperature is too high, the cooling effect of the air conditioner is deteriorated, which is normal.
  • H
    hespinozaAug 18, 2025
    How to fix a Midea MOV-150HN1-R that does not run?
    • A
      Amanda JohnsonAug 19, 2025
      If the system isn't running, it might be due to a power supply failure. Operate it after the power supply resumes, ensuring it's properly connected. Also, check the remote controller or wired controller. If the fuse blows or the circuit breaker trips, replace the fuse or check for electrical leakage.
  • S
    Stephanie TaylorAug 29, 2025
    Why is the heating effect poor in my Midea MOV-150HN1-R Air Conditioner?
    • L
      lnixonAug 30, 2025
      A poor heating effect can occur if the outdoor temperature is below -7°C; in this case, use a heating device because the unit cannot operate normally. Ensure that all doors and windows are tightly closed. Also, the refrigerant may be leaking or deficient, requiring leak detection and refilling to the correct quantity.

Summary

Part 1 General Information

Part 2 Med-static Pressure Duct Indoor Unit

Part 3 Hi-static Pressure Duct Indoor Unit

Part 3 Floor-standing Indoor Unit

Features

Highlights key characteristics and benefits of the unit.

Part 4 Outdoor Unit

Specifications

Technical details and performance data for the outdoor unit.

Part 5 Installation

Installation of Duct Type Indoor Units

Procedures for installing duct-type indoor units.

Installation of Floor Standing Type Indoor Units

Procedures for installing floor-standing indoor units.

Installation of Outdoor Units

Procedures for installing outdoor units.

Connection of Refrigerant Pipe

Guidelines for connecting refrigerant pipes between units.

Heat Insulation of Refrigerant Pipe

Instructions for insulating refrigerant pipes.

Electric Connection

Procedures for making electrical connections.

Trial Run

Steps for performing the initial startup and testing.

Part 6 Controller

Midea MOV-150HN1-R Specifications