7.Troubleshooting
7.1 Indoor unit
Failure phenomenon Operation lamp Timer lamp
Indoor fan speed has been out of control for over 1 minute
X
Indoor room temp. sensor or evaporator temp. sensor is open circuit
or short circuit
on
EEPROM error on
Over current protection of the compressor occurs 4 times in 1h X
r Extinguish
Flash at 5Hz
On Light
7.2 Outdoor unit
Failure phenomenon LED1 LED2 LED3
Stand by
High temp. protect of condenser
Temp. sensor in condenser 1 is open circuit or short circuit
Temp. sensor in condenser 2 is open circuit or short circuit
Flash at 2Hz