Anti frozen at cooling mode 
 
10.4 Protection 
10.4.1 3 minutes delay at restart for compressor. 
10.4.2 Sensor protection at open circuit and breaking disconnection 
10.4.3 Fan Speed is out of control. When Indoor Fan Speed is too high(higher than High 
Fan+300RPM)or too low(lower than 400RPM), the unit stops and LED displays failure information 
and can’t returns to normal operation automatically. 
10.4.4 Cross Zero signal error warning. If there is no Cross Zero signals in 4 minutes, the unit stops 
and LED displays failure information and can’t returns to normal operation automatically. 
10.4.5 The current protection of the compressor 
 
If compressor turns off for continuously 4 times due to current protection in 5 minutes from 
Compressor On, the unit stops and LED displays failure information and can’t returns to normal 
operation automatically. 
 
10.5 Fan-only mode 
Fan speed is high/mid/low/ Auto 
 
10.6 Cooling mode 
The 4-way valve is closed at cooling mode. 
The action of the compressor and the outdoor fan:(T=indoor temperature)