Service manual 
- 41 - 
 
 
10.12.4  Auto: 
After an hour running under economic mode, the set temp will rise 1℃,if it is under cooling mode; the 
set temp will decrease 1℃,if it is under heating mode; the set temp will be changeless, if it is under 
fan-only mode; the condition will be the same after the air conditioner running under economic mode 
after 2 hours, and during the next time the set temp do not change. The total time is 7 hours, after 7 
hours the unit stops. 
 
10.13 Auto restart function 
In case of a sudden power failure, this function automatically sets the unit to previous settings before 
the power failure when power returns 
 
10.14 Anion (optional) 
Starts with indoor fan.