Indoor
Conditions
25ÂșC 30ÂșC 35ÂșC 40ÂșC 45ÂșC 50ÂșC
21ÂșC D Total capacity kW 2.50 2.35 2.17 2.00 1.87 1.73
15ÂșC W Sensitive capacity kW 1.82 1.75 1.64 1.52 1.43 1.34
Input kW. 0.86 0.90 0.94 1.02 1.13 1.17
24ÂșC D Total capacity kW 2.71 2.58 2.42 2.28 2.13 1.96
17ÂșC W Sensitive capacity kW 1.99 1.93 1.84 1.75 1.64 1.52
Input kW. 0.88 0.93 0.97 1.05 1.16 1.20
27ÂșC D Total capacity kW 2.88 2.75
2.60
2.46 2.29 2.11
19ÂșC W Sensitive capacity kW 2.19 2.12
2.03
1.93 1.80 1.67
Input kW. 0.91 0.96
1.00
1.08 1.20 1.24
32ÂșC D Total capacity kW 3.21 3.08 2.98 2.77 2.53 2.38
23ÂșC W Sensitive capacity kW 2.47 2.40 2.34 2.19 2.02 1.93
Input kW. 0.95 1.00 1.04 1.12 1.25 1.29
OUTDOOR TEMPERATURE DRY
9.4 MSG-09HRN2
SUMMER
Coolin
Indoor
Conditions
25ÂșC 30ÂșC 35ÂșC 40ÂșC 45ÂșC 50ÂșC
21ÂșC D Total capacity kW 2.50 2.35 2.17 2.00 1.87 1.73
15ÂșC W Sensitive capacity kW 1.82 1.75 1.64 1.52 1.43 1.34
Input kW. 0.86 0.90 0.94 1.02 1.13 1.17
24ÂșC D Total capacity kW 2.71 2.58 2.42 2.28 2.13 1.96
17ÂșC W Sensitive capacity kW 1.99 1.93 1.84 1.75 1.64 1.52
Input kW. 0.88 0.93 0.97 1.05 1.16 1.20
27ÂșC D Total capacity kW 2.88 2.75
2.60
2.46 2.29 2.11
19ÂșC W Sensitive capacity kW 2.19 2.12
2.03
1.93 1.80 1.67
Input kW. 0.91 0.96
1.00
1.08 1.20 1.24
32ÂșC D Total capacity kW 3.21 3.08 2.98 2.77 2.53 2.38
23ÂșC W Sensitive capacity kW 2.47 2.40 2.34 2.19 2.02 1.93
Input kW. 0.95 1.00 1.04 1.12 1.25 1.29
OUTDOOR TEMPERATURE DRY
WINTER
-7ÂșC D
-8ÂșC W
Capacity kW
3.80 3.33 3.05 2.68 2.31 2.03
Input kW.
1.18 1.07 1.00 0.92 0.81 0.73
Capacity kW
3.73 3.27 2.98 2.58 2.19 1.90
Input kW.
1.21 1.09 1.01 0.95 0.83 0.74
Capacity kW
3.70
3.22
2.94 2.52 2.07 1.72
Input kW.
1.25
1.10
1.05 0.97 0.85 0.78
Capacity kW
3.66 3.18 2.90 2.48 2.04 1.69
Input kW.
1.29 1.11 1.06 1.01 0.91 0.81
15ÂșC
18ÂșC
20ÂșC
22ÂșC
OUTDOOR CONDITIONS
Indoor
Conditions
12ÂșC D
11ÂșC W
7ÂșC D
6ÂșC W
4ÂșC D
3ÂșC W
0ÂșC D
-1ÂșC W
-4ÂșC D
-6ÂșC W