8.10 Automatic operation mode
When running in automatic mode, the air conditioner automatically selects one of the
following operation modes: cooling, heating or fan only according to the temp. difference
between room temp. (TA) and set temp. (TS).
TATS
Operation mode
TATS>2
Cooling
-1℃≤TATS+2
Fan-only
TATS<-1
Heating (air-only for cooling only type)
at auto mode, the indoor fan blows automatically in selected mode.
8.11 Forced cooling function
A: Select forced cooling function with the forced cooling button or the switch.
B: The compressor is unconditionally turned on, after 30 minutes cooling operation whose fan
mode is set as low, the A/C operates at DRY mode with a set temp. of 24.
C: All protections of remote control cooling are available at forced cooling operation.
8.12 Forced Auto function
A: Select forced auto function with the forced auto button or the switch.
B: In forced auto status the A/C operates at remote control mode with a set temp. of 24.
8.13 Timer Function
8.14 Economic Running
Cooling: The set temperature rise 1 per hour. Two hours later, the set temperature will
maintain as a constant and the air circulation is kept at low speed.
Heating: The set temperature decrease 1 per hour. Two hours later, the set
temperature will maintain as a constant and the air circulation is kept at low speed (Cold air
proof function takes priority over all).
Auto: The economic running function operates in accordance with the selected running
mode by the auto mode.