Service manual
- 6 -
3 Specification
MSV1-07CRN1 MSV1-07HRN1 MSV1-09CRN1 MSV1-09HRN1
Ph-V-Hz
1, 220-240V~, 50Hz 1, 220-240V~, 50Hz 1, 220-230V~, 50Hz 1, 220-230V~, 50Hz
Capacity Btu/h 7000 7000 9000 9000
Input W 640 640 820 820
Rated current A 2.8 2.8 3.6 3.6
EER Btu/w.h 10.9 10.9 3.2 , 10.9 3.2 , 10.9
Capacity Btu/h —— 8000 —— 10300
Input W —— 650 —— 840
Rated current A —— 2.9 —— 3.7
COP W/W —— 12.31 —— 12.28
A5 5 5 6
A 15 15 21.7 21.7
Model PA82X1C-4DZDE PA82X1C-4DZDE PA108X1C-4FTDE PA108X1C-4FTDE
Type ROTARY ROTARY ROTARY ROTARY
Brand TOSHIBA TOSHIBA TOSHIBA TOSHIBA
Capacity Btu/h 6650 6650 8870 8870
Input W 680 680 915 915
Rated current(RLA) A 3.04/2.85 2.85 4 4
Locked rotor Amp(LRA) A 15 15 21.7 21.7
Thermal protector B135-135-241E/MRA1340
Model RPG20D RPG20D RPG20D RPG20D
Brand Welling Welling Welling Welling
Input W 32 32 38 38
Capacitor uF 1.2 1.2 1.2 1.2
Speed(hi/mi/lo) r/min 1040/900/800 1040/900/800 1040/900/800 1040/900/800
m3/h 450 450 550 550
dB(A) 36/33/30 36/33/30 38/35/32 38/35/32
Model YDK24-6T YDK24-6T YDK24-6F YDK24-6F
Brand Welling Welling Welling Welling
Input W 56 56 56 56
Capacitor uF 2.5 2.5 2.5 2.5
Speed r/min 800 800 800 800
m
3
/h
1500 1500 1800 1800
dB(A) 54 54 54 54
g R410A/800 R410A/820 R410A/900 R410A/900
MPa 4.2 4.2 4.2 4.2
Liquid side/ Gas side mm
Ф
6.35/
Ф
9.53
Ф
6.35/
Ф
9.53
Ф
6.35/
Ф
9.53
Ф
6.35/
Ф
9.53
Max. refrigerant pipe length
m10 10 10 10
Max. difference in level m 5 5 5 5
℃
17-30 17-30 17-30 17-30
℃
18-43 -7-43 18-43 -7-43
m
2
10-14 10-14 14-21 14-21
Operation temp
Ambient temp
Application area
Outdoor noise level
Refrigerant type R410A
Design pressure
Refrigerant
piping
Indoor air flow (Hi/Mi/Lo)
Indoor noise level (Hi/Mi/Lo)
Outdoor
fan motor
Outdoor air flow
Max. current
Starting current
Compressor
Indoor
fan motor
Model
Power supply
Cooling
Heating
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are
normally somewhat different as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product
improvement.