Service manual
- 26 -
Select forced auto function with the forced auto button or the switch.
In forced auto status the A/C operates at remote control mode with a set temp. of 24℃
Manual operation is controlled by touching buttons and divided into force cooling and forced auto mode.
It transfer between these two modes by pressing the buttons, the cycling order of the button press is as
below graph show to you.
7.12 Sleep mode
7.12.1 The sleep function is available at cooling, heating or auto mode
7.12.2 Cooling:
The set temperature rise 1 per hour. Two hours later, the set temperature will maintain as a ℃
constant and the fan speed is kept at low speed.
7.12.3 Heating:
The set temperature decrease 1 per hour. Two hours later, th℃ e set temperature will maintain as
a constant and the air circulation is kept at low speed (Anti-cold function takes precedence over all).
7.12.4 Auto:
After an hour running under economic mode, the set temp will rise 1 ,℃ if it is under cooling mode;
the set temp will decrease 1 ,if it is under heating mode; the set temp will be changeless, if it is℃ under
fan-only mode; the condition will be the same after the air conditioner running under economic mode