Water flow adjusting
valve with filter
Cold water inlet
Water flow adjusting
valve with filter
Cold water inlet
Water flow adjusting
valve with filter
Cold water inlet
Fig.4
NOTE:
1. Water
adjusting valve with must be used when install the unit.
2. Blue marker stands for water inlet, red marker stands for water outlet;
3. Do not overexert to avoid damaging the water heater.
5. POWER SUPPLY CONNECTION
a. Adjust power selection knob to “OFF”;
b. Choose air switch with leakage protection according to power of water heater;
c. When connecting the water heater to electric network, please pay attention to
connect live line (red/brown), neutral line (blue) and earth line (yellow/green) with
corresponding line in electric network.
NOTE:
1. A private power cord should be used for this unit.
2. After connecting to electric network, please check the earth condition and make sure
the earth resistance is <4Ω.
6. WATER SUPPLY
After all the plumbing is connecting, open water inlet valve of the product and
supply water to the unit to drain away air inside until there is stable water
comes
out from shower head. Check whether there is leakage at joints or not. If there is, check
whether the connecting parts are fastened or not, then re-supply water.