9. Troubleshoot of abnormal phenomena
Air supply motor stop automatically to defrost.
At the beginning and the end of the defrost process, sound is give out in
motor valve occur.
During the process or just after have stopped, sound like water flow occur,
which will be amplified at the first 2~3 minutes, this is caused by process
of refrigerant current or water discharge at dehumidifying operation.
Slight ”hiss” is caused by heat exchanger as temperature changes. The
sound give out because of heat expands and cold contracts of heat
exchanger.
During the beginning or just after have stopped, sound like clock occur,
which is caused by electric expanding valve operation.
Whether the power is cut.
Whether the manual power supply switch is off.
Whether fuse is broken.
Whether the protection device works.(Operation lamp is lightened.)
Whether it is the time set.(Operation lamp is lightened.)