Service Manual, 2016-12
31 / 42
The characteristic that resistance value reduces as the temperature increases is deemed to have negative
slope or negative temperature coefficient (NTC), and such thermistor is called as NTC thermistor. The
resistance value changes sensitively with temperature and typically changes 7% ~ 3% per degree
centigrade. Sensor used in the refrigerator is NTC thermistor.
There is following computing formula for the sensor:Sampling voltage / reference voltage =
R1 / (RNTC + R1)
AD value / reference AD value = R1 / (RNTC + R1)
The reference voltage is 5V, RNTC is the resistance value of the sensor, R1 is R31\R32\R33 in schematic
diagram that is 5.1K
10.4Fan motor circuit of the freezing chamber(None)
10.5Refrigerator fan motor circuit (None)
10.6Condensing fan motor circuit (None)
10.7Damper motor circuit (None)
10.8Resistance value of the sensor (R/T)
Tx()
RKΩ
Tx()
RKΩ
Tx()
RKΩ
Tx()
RKΩ
Tx()
RKΩ
-30
33.81
-15
14.31
0
6.495
15
3.141
30
1.617
-29
31.85
-14
13.55
1
6.175
16
2.999
31
1.55
-28
30.01
-13
12.83
2
5.873
17
2.865
32
1.486
-27
28.29
-12
12.16
3
5.587
18
2.737
33
1.426
-26
26.68
-11
11.52
4
5.315
19
2.616
34
1.368
-25
25.17
-10
10.92
5
5.06
20
2.501
35
1.312
-24
23.76
-9
10.35
6
4.818
21
2.391
36
1.259
-23
22.43
-8
9.82
7
4.589
22
2.287
37
1.209
-22
21.18
-7
9.316
8
4.372
23
2.188
38
1.161
-21
20.01
-6
8.841
9
4.167
24
2.094
39
1.115
-20
18.9
-5
8.392
10
3.972
25
2.005
40
1.071