28
If other failures are encountered, stop use of the water heater immediately, and notify
the professional maintenance department for repair. The users shall not remove or repair
the water heaters without prior permission, otherwise an accident might occur.
●
The following phenomena are not faults:
Phenomena
White smoke from the
exhaust port
When the hot water is too small,
it turns into cold water
Fan will not stop immediately
after turn of the water
Water outlet speed is slow
Water temperature is higer than
set temperature in summer
Explain
The outdoor temperature is too low, causing the water
vapor in the exhaust to solidify
The water inlet is too small,and the machine stopped
working
Temperature of inlet water is too low with high water
flow has exceed the heating capacity of the machine.
Turn down the water flow
Hot water can't come out in
winter
Low temperature water can't
come out in summer
Temperature of inlet water is too high.Turn up the water
flow
The machine will stop automatically after 40 minutes of
continuous operation to prevent hypoxia.
Flameout after working for
40mins
Fan will work for a while after stop using the machine to
cool inside and exhaust gas
Water pressure change caused by multiple hot water use
points
Water temperature fluctuation
Water pressure is too low with high inlet temperature may
cause minimum temperature is higher than set temperature
The hot water pipe is too long
CERTIFICATIONS
AND SAFETY APPROVALS
We hereby confirm that the following customer model names and Midea model names
match each other respectively.
Certificate No:GB 005500 001
PIN: CE-2806DN0131
Manufacturer:WuHu Midea Kitchen & Bath Appliances Manufacturing Co., Ltd.
East Road Wanchun, East Area, Economic & Technological Development Area, Wuhu
City, Anhui Province, 241000, P.R. China
Brand Midea mode Marketing Model
JSG22-11VLS
JSG26-13VLS
MGWH11-22EGPGR(W)
MGWH13-26EGPGR(W)
Midea
Midea
Declaration of conformity