22 | Page
1 0-293-1 REV E
The Brat Solar Charge Controller Instructions
Optional Accessories
MNPV Series Combiners
When combining more than two strings code requires fuses or breakers on each string. This is
because if a fault occurred in one string the output current of the other strings would gang up on the
faulted panel with predictable results. Midnite MNPV combiners prevent this situation while making
installation a breeze. Models with MC4 connectors offer Plug N Play connection to the solar panels
and convenient wiring to the rest of the system. A combiner with circuit breakers also provides a
convenient disconnect for the solar panels.
Type 3R Rainproof construction allows outdoor installation
MNEPV Breakers and MNTS Touch Safe fuses
and Fuseholders
MidNite Solar MNEPV breakers and MNTS Touch safe
fuseholders are agency approved Dinrail mount circuit
protection. Available in a wide range of sizes. All MidNite
circuit breakers can be used at 1 00% rated current when
mounted in a MidNite enclosure.
Breaker / Fuseholder Torque Value: 20 In-Lbs (2.3NM)
MNEPV BREAKER
MNTS FUSEHOLDER