3.2 Output mode
➣ PV priority mode: Loads are powered by the PV module and battery. Diversified charging mode
and output mode are optional. When PV priority mode is selected, utilization of green solar
energy can be maximized to achieve energy saving and emission reduction.
Switch to mains supply when the PV charging is not available. This mode maximizes the use of solar energy
while maintaining battery power, suitable for use in the areas with relatively stable grid.
➣ Mains priority mode: Switch to inverter only when the mainsare not available .
Then, the unit is equivale n t to a backup UPS, suitable for areas with unstable grid.
Inverter priority mode: Switch to mains supply only when the battery is under voltage. This
mode maximizes the use of DC power and is best suited for areas with a stable grid.
➣