10-527-1 MN3024DIY REV A
MN3024DIY
User Manual
10
PV reverse polarity
protection
When the PV polarity is reversed, the unit will not be damaged.
11
AC reverse
protection
Prevents the inverter output from backfeeding into the AC input.
12
Bypass over current
protection
Built-in AC input overcurrent protection circuit breaker.
13
Battery input over
current protection
When the battery current into the inverter exceeds the current limit for one
minute, the inverter stops and switches to AC bypass mode.
14
Battery input
protection
If the battery is connected backward or the there is a short circuit, the
battery input fuse will blow reducing the risk of damage or fire.
15
Charge short
protection
If a short circuit or an excessive overload occurs when charging the battery,
charging will stop.