Every change of the factory setting
should be documented in case of
possible technical service.
Record any changes in the field
"Adjusted value___________".
1. Setting the cold water inlet from:
"Nominal water intake" to "Nominal
water intake+1l".
The amount of water taken into the
machine at each intake can be
increased by 1 liter to a maximum of
9.5 liters.
^ Turn the program selector to "STOP".
^ Turn the machine off.
^ Press and hold the "Display" and "Start"
buttons, at the same time turn the
machine on with the "On / Off button".
The displays shows the current
program status "P...".
The "Fill/Drain" indicator lights.
^ Press the "Extra Drying" button once.
"E01" (programming level 1) is
displayed.
^
Turn the program selector to "China &
Crystal".
Either "10" or "11" is displayed.
"10" = Nominal water intake
"11" = Nominal water intake + 1 liter
^
Press "Display" to change from "10" to
"11" or vice versa.
^
Press the "Start" button. "SP" is
displayed.
^
Press the "Start" button again. The
change has been saved.
Value set:
2. Selecting a second interim rinse
A second interim rinse "Interim rinse II"
can be programmed to improve interim
rinsing in all programs (except for
"Rinse" and "Rapid").
^
Turn the program selector to "STOP".
^
Turn the machine off.
^
Press and hold the "Display" and
"Start" buttons, at the same time turn
the machine on with the "On / Off"
button.
The display shows the current
program status "P...".
The "Fill/Drain" indicator lights.
^ Press the "Extra Drying" button once.
"E01" (programming level 1) is
displayed.
^ Turn the program selector to "Rapid".
"30" or "31" is displayed.
"30" = without interim rinse II
"31" = with interim rinse II.
^ Press "Display" to change from "30" to
"31" or vice versa.
^
Press the "Start" button. "SP" is
displayed.
^
Press the "Start" button again. The
change has been saved.
Value set:
Programming special functions