Converting to another gas type
51
Functional check
Check all gas fittings for leaks.
Reassemble the hob.
Ignite all burners to check that they
are operating correctly.
The flame must not go out on the
lowest setting, or when the control is
turned quickly from the highest to the
lowest setting.
On the highest setting, the flame
must have a distinctive and visible
core.
Adhere the label supplied with the
jets, stating the type of gas being
used.