Water connection
86
A tap with a 3/4 " male thread must
be pr
ovided on site.
Connection to the mains water sup‐
ply should only be carried out by a
quali
fied and competent person in
strict accordance with national and
local safety regulations.
The tap should be easily accessible
once the appliance has been built in.
The water pressure (flow pressure at
the tak
e-off point) must be between
30 and 1000 kPa (0.3 and 10 bar). If
the water pressure is lower than this,
the fault message Water intake will
appear in the display (see "Problem
solving guide"). If the water pressure
is too high, a pressure reducing valve
must be fitted.
After connecting the dishwasher to
the water supply, check that all
plumbing connections are watertight.
T
o avoid any damage to the ap‐
pliance, the dishwasher must only be
connected to a fully vented plumbing
system.
The inlet hose must not be
sh
ortened or damaged in any way as
it contains electrical components
(see illustration).