EasyManua.ls Logo

Miele PW 5065 - Fault messages in the display

Miele PW 5065
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault messages in the display
Message in the display Possible cause Remedy A
q
Drainage fault
The water outlet is
blocked or restricted.
LP version: Clean the drain
filter and the drain pump.
AV version: Call the Miele
Professional Service
Department.
The drain hose has
been fixed too high.
The maximum drain height
is1m.
p
Water inlet fault
The water inlet is
blocked or restricted.
Check whether
the tap is opened wide
enough.
the inlet hose is kinked.
o
Waterproof system
has reacted
The water protection
system has reacted.
Close the tap.
Call the Miele
Professional Service
Department.
,
Technical fault.
Call Service
There is a fault. Start the programme
again.
If the fault message
appears again, contact the
Miele Professional Service
Department.
,
Fault
Disinfection temp.
not
reached
During the disinfection
programme the water
temperature was not
reached.
The machine has not
carried out the disinfection
cycle correctly.
Start the programme
again.
A To switch off the fault message, press the OK button.
Problem solving guide
44

Table of Contents

Other manuals for Miele PW 5065