Programming
145
12. Dispensing
phase 1
Determines the dispensing concentration for max. 6dispenser
pumps.
Choose from the following options:
– No
Detergent is not dispensed.
– User defined
– Dispenser pump
1 dispenser pump per dispensation
selectable from D1 to D13
– Dispensing amount (depending on dispensing method)
0 to 9999ml or
0 to 999ml/l or
0 to 999ml/kg
– Dispensing delay
0 to 999 sec.
– with dispensing method "No"
13. Dispensing
stop 1
Dispensing process control
Choose from the following options:
– No
The dispensing runs simultaneously to the subsequent programme
steps. As a result, the dispensing is discontinued at the end of the
subsequent Wash time 1.
Yes
Long dispensing phases are not cancelled. The following Wash time1
begins after the end of the dispensing.
– with dispensing method "No"
14. Agitation from
level
Drum agitation for the first water intake in the programme block.
Choose from the following options:
– Automatic
– User defined
– Automatic
– User defined
Duration: 0.15 to 59 sec.
0 to 99 min.
Rhythm:
No
Normal 12/3 sec. Wash / Pause
Gentle 5/10 sec. Wash / Pause