Reprogramming possibilities
Program
alterations
Position
of the
Program
selector
Options Notes Enter
program
changes
here
Standard
setting
Wet
clean
Bed-
ding
Adjust
-
able
Cotton Reversing time* in the
Cotton Programs 1 to
6 and Timed drying
programs10 & 11
A A
1 min
and
27 secs
25
secs
25
secs
20 secs
to
2 mins
*) Drum reverses to
the left and to the right
in programmed timed
intervals
Reversing off /
Pause interval in
Cottons programs
1 to 6 and
Timed drying
programs 10 & 11
B
3
secs
10
secs
0 (Off)
or
2 to 10
secs
Residual moisture /
Prog. selection with
the Selector button
C
see chart
"Proramm-
able re
-
sidual
moisture
Call up the residual
moisture values to be
changed with the se
-
lector button and alter
with the start button.
Fan heating in pause
times
D
1 0 0 0 or 1 1 = On
0 = Off
Cooling down
temperature
Vented air
E
50 °C 40 °C 30 °C
to
60°C
Reversing time* in the
Minimum iron
programs 7 to 9
F
1 min
27 secs
55
secs
20 secs
to
2 mins
Mini-
mum
iron
Reversing off /
Pause interval
in Minimum iron
programs 7 to 9
B G
3 secs 0 (Off)
or
2 to 10
secs
without heating
Program 10
H
15 mins 3 mins
to
1 hour
with heating followed
by Cooling down
Program 11
I
20 mins 3
mins
3 mins
to
3 hours
add to this cooling
down time to a cool
temperature of 50 °C
(Standard value)
Timed
drying
Additional display
during operation
C J
0 2 0, 1 or
2
0 = Residual moisture
(temperature display
for 5 secs, after the
selector button is
pressed)
1 = temperature only
2 = residual moisture
only
__
K
__ __ Program position is
empty.