Electrical connection
The electrical connections to the dryer must
be in accordance with instructions given on
the installation diagram and comply with lo
-
cal regulations.
Once installed in position all detachable
outer casing parts must be refitted.
THIS APPLIANCE MUST BE
GROUNDED.
Before installation, make sure that the volt
-
age and frequency listed on the data plate
correspond with the site electrical supply.
The dryers are ready for connection to a 208
V, 60 Hz, 20 A power supply.
Make the electrical connection (L1, L2, L3,
Ground) at the terminal block. Follow the in
-
structions given on the enclosed wiring dia-
gram (located on the terminal block).
WARNING
Verify that the unit is in-phase:
–
the ventilation motor should turn clockwise
(open the panel to the lint filter.)
–
the dryer door should suck in from the un
-
der pressure.
All removable outer housing parts must be
refitted after the electrical connection has
been made.
The electrical rating:
18.0 kW T6351
7.0 kW T6551
6.0 kW T6751
Installation
28