GUIDE RAPIDE
OMEGA
2
BASIC II
F
50
113770 I
Procédé 1,0 mm 1,5 mm 2,0 mm 3,0 mm
Matériau Fil Gaz S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
Fe 0.8 CO
2
2.5 19.0 4.5 19.5 7.0 21.0 11.0 27.0
Fe 1.0 CO
2
2.0 18.0 2.5 19.0 3.0 20.0 4.5 21.0
Fe 1.2 CO
2
1.0 18.0 2.0 20.0 2.5 21.0 3.5 22.0
Fe 0.8 ArCO
2
3.0 16.0 6.0 18.0 7.5 19.5 11.0 20.0
Fe 1.0 ArCO
2
2.0 15.0 3.0 16.0 4.0 17.0 6.0 19.0
Fe 1.2 ArCO
2
1.5 16.5 2.5 17.5 3.5 18.0 4.5 20.5
Fe 1.6 ArCO
2
1.0 17.0 2.0 18.0 2.5 18.5
CrNi 1.0 ArCO
2
3.0 15.0 4.0 16.0 6.0 17.0 8.5 20.0
CrNi 1.2 ArCO
2
2.0 15.0 3.0 16.0 3.5 16.5 6.0 18.0
AI 1.0 Ar 4.0 14.5 6.0 15.0 7.5 16.0 9.0 19.0
AI 1.2 Ar 3.5 13.0 5.0 15.0 8.0 16.0 9.0 17.0
Procédé 4,0 mm 6,0 mm 10,0 mm
Matériau Fil Gaz S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
Fe 0.8 CO
2
13.0 29.0 18.0 30.0 24.0 37.0
Fe 1.0 CO
2
6.0 22.5 9.0 24.5 14.0 32.0
Fe 1.2 CO
2
4.5 23.0 7.5 28.5 11.0 36.0
Fe 0.8 ArCO
2
14.0 26.0 18.0 31.0 24.0 33.0
Fe 1.0 ArCO
2
8.0 20.0 11.5 26.5 16.0 30.0
Fe 1.2 ArCO
2
5.5 20.5 8.0 29.0 10.0 32.0
Fe 1.6 ArCO
2
3.0 19.5 4.0 22.0 5.5 29.0
FeFlux 1.2 ArCO
2
6.0 21.0 8.0 25.0 11.0 28.0
CrNi 1.0 ArCO
2
9.0 25.0 10.0 27.0
CrNi 1.2 ArCO
2
8.0 24.0 10.0 24.0 12.0 31.0
AI 1.0 Ar 11.0 22.0 13.0 25.0 15.0 27.0
AI 1.2 Ar 10.0 18.0 13.0 23.0 15.0 26.0
Tableau de soudage (consigne) BASIC II - Valeur usine
Possibilités de réglage Plage de réglage Précision Valeur usine Unité
2T/4T
Paramètres principaux :
1 Vitesse fil OMEGA
2
300 1.5 - 18.0 0.1 3.0 m/min
Vitesse fil OMEGA
2
400/550 1.5 - 27.0 0.1 3.0 m/min
2 Tension d’arc OMEGA
2
300 13 - 32 0.1 18.0 V
Tension d’arc OMEGA
2
400/550 13 - 37 0.1 18.0 V
Paramètres secondaires :
1 Réglage self (dureté d’arc) -5.0 - +5.0 0.1 0.0 -
2 Pré-Gaz 0.0 - 10.0 0.1 0.2 s
3 Dévidage fil froid Off / 1.5 - Max. 0.1 2.0 m/min
6 Burnback 1 - 30 1 5 ms
7 Post-Gaz 0.0 - 10.0 0.1 3.0 s
t Pointage (tempo) 0.0 - 50.0 0.1 0.0 s
G Gaz Manuel 0.5 - 27.0 l
r Commande à distance 0 = interne
1 = réglage à la torche
2 = commande à distance
C Cooling (Refroidissement) ON / OFF
L Fonction de verrouillage ON / OFF