Specifications for electrical supply, current, and fuses.
Details for water inlet, outlet, and drain connections.
Guidelines for competent person installation and mounting.
Connection requirements for water supply and hose.
Information on system filling pressure and high pressure advice.
Pipework recommendations for system connection and expansion vessel.
Details on water discharge after filling and tundish connection.
Physical dimensions of the unit.
Schematic showing the unit's connection within a heating system.
Dimensions and clearances required for wall mounting.
Wiring diagram for unit connections and alarms.
Summary of electrical specifications, fuses, and relay ratings.
How to scroll through unit settings.
Function of the 'Up' button in service mode.
How to turn the unit on/off.
Function of the 'Down' button in service mode.
How to enter and use service mode.
Indicates normal system pressure within set parameters.
Shows the unit is currently filling the system.
Alerts when inlet pressure is too low to fill the system.
Warns of potential leaks due to frequent system top-ups.
Step-by-step guide for modifying unit parameters.
Setting the required system pressure when cold.
Setting the pressure for the low pressure alarm.
Setting the pressure for the high pressure alarm.
Displays water usage and operating time (informational).
Configures flood protection based on pressure increase.
Time to continue filling after reaching cold fill pressure.
Warns of potential leaks based on frequent top-ups.
Time the unit waits before operating after pressure drops.
Option to alter the unit's time and date settings.
Enables or disables the audible alarm for faults.
Provides access to the last five registered faults.
Enables or disables flood protection for leaks.
Indicates a leak is preventing pressure increase during filling.
Indicates low system pressure when leak alert is enabled.
Unit stops filling due to insufficient incoming water pressure.
Indicates frequent operation suggesting a potential leak.
System pressure exceeds high alarm setting.
Indicates a potential issue with the unit's pressure sensors.
Further details on sensor failure due to voltage instability.
Indicates a blocked solenoid valve or failed non-return valve.
How to use manual override to correct sensor failure issues.
List of replaceable components with their part codes.
Steps to detach the unit's control housing.
Procedure for cleaning solenoid valves due to blockage.
Steps to clean the filter in the inlet ballofix valve.
Statement of compliance with EMC and LVD directives.