77
Channel Setting
Item
Description
Name
Set the name to identify the remote channel. It cannot be blank.
Slave ID
Set Modbus slave ID.
Address
The starting address for Modbus reading.
Number
The reading quantity from starting address.
Command
Type
Read command data type, options are Coil, Discrete, Holding Register (INT16),
Input Register (INT16), Holding Register (INT32) and Holding Register (Float).
Link Type
Select serial port or TCP connection.
Serial Port: the router communicate with devices via Modbus RTU protocol.
TCP: the router communicate with devices via Modbus TCP protocol.
Remote
Device IP
When link is TCP, fill in the IP address of the remote Modbus TCP device.
Port
When link is TCP, fill in the port of the remote Modbus TCP device.
Sign
When command data type is holding register or input register, enable or disable to
identify whether this channel is signed.
Decimal
Place
When command data type is holding register or input register, indicate a dot in the
read into the position of the channel. For example: read the channel value is 1234
and a Decimal Place is equal to 2, then the actual value is 12.34.
TCP Forwarding
Item
Description
Name
The name of Modbus Master's channel.
IP
The IP address of the server to which the packets are forwarded .
Port
The port of the server's to which the packets are forwarded.
6.4.4 GPS
Users can enable GPS feature here. For more debug information, please also enable GPS log.