EasyManua.ls Logo

Millimar C 1208 User Manual

Millimar C 1208
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Mahr GmbH, Standort Esslingen, Reutlinger Straße 48, 73728 Esslingen
Tel. +49711 9312-600, Fax +49 711 9312-756 mahr.es@mahr.de, www.mahr.de
Operating Instructions
3723047
Millimar C 1208 /C 1216 / C 1240
08.11 .2016

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Millimar C 1208 and is the answer not in the manual?

Millimar C 1208 Specifications

General IconGeneral
BrandMillimar
ModelC 1208
CategoryMeasuring Instruments
LanguageEnglish

Summary

Permitted Uses of Millimar C Series

Millimar C Series Instrument Versions

Describes available versions: C 1208/C 1216 M, T, F; C 1208 PE; C 1240 M.

Operating Instructions Symbols

General Information Symbol

Symbol indicating general information within the operating instructions.

Important Information Symbol

Symbol indicating crucial information for correct operation or safety.

Disposal and Warranty Information

Electronic Device Disposal Guidelines

Guidelines for environmentally friendly disposal of electronic devices and batteries.

Warranty Voidance Conditions

Conditions related to storage temperature and humidity that invalidate the warranty.

Safety Instructions

General and Electrical Safety Precautions

Guidelines for safe connection, voltage checks, and power socket usage.

Operational and Handling Safety Precautions

Precautions for probe connection, environment, handling, and cleaning.

Initial Commissioning Procedures

Unit Setup and Initial Configuration

Steps for unpacking, connecting power, probes, and initial display settings.

Display and Measurement Settings

Setting language, units, display range, and probe connection formulas.

Initial Commissioning: Parameter Management

Navigating the Function Catalog

How to navigate through the instrument's function and parameter catalog using keys.

Modifying Numerical Parameter Values

Step-by-step guide on changing numerical values for various settings.

Millimar Control Elements

Display and Keypad Overview

Introduces the display and keypad as primary control interfaces.

Keypad Operation Details

MENU, DATA, MASTER Key Functions

Explains the operation of MENU, DATA, and MASTER keys for navigation and input.

Keypad Operation and System Settings

ESC Key Functionality

Describes the ESC key's role in navigating menus and exiting modes.

Restoring Factory Settings

Steps to restore the instrument to its original factory settings via the ESC key.

Keypad Operation Details

RANGE Key Functionality

How to select and change the display range for measurements.

SELECT Key Functionality

Explains the programmable SELECT key for quick access to functions.

Keypad Operation and Status Indication

TEST and START Key Operations

Details the function of TEST and START keys for setup and measurement.

Status Indicators

Describes the meaning and use of status lamps for measurement feedback.

Interface Connections and Setup

Serial RS 232 Interface Configuration

Details the setup and use of the serial RS 232 interface for data transfer.

Parallel I/O Interface Configuration

Explains the parallel interface for connecting external devices and signals.

Performing Basic Settings

Selecting Display Language

Procedure to set the user interface language.

Performing Basic Settings

Adjusting Display Contrast

How to adjust the screen contrast for optimal visibility.

Performing Basic Settings

Setting Measurement Units

How to choose between millimeters, micrometers, or inches for measurement display.

Performing Basic Settings

Setting Display Resolution and Format

Configuring the number of decimal places and display format for measured values.

Performing Basic Settings

Configuring Displayed Features

Setting whether one or two features are displayed simultaneously.

Probe Setup and Positioning

Inserting and Positioning the Probe

Steps for correctly inserting and positioning probes for accurate measurements.

Probe Sensitivity Alignment

Understanding Probe Sensitivity Variations

Explains variations in probe sensitivity and when alignment is necessary.

Probe Sensitivity Alignment

Calibrating Measuring Channel C1

Procedure for calibrating the measuring channel for probe C1.

Probe Sensitivity Alignment

Aligning C2 Probe Sensitivity to C1

Steps to align the sensitivity of the probe connected to C2 with C1.

Feature Calculation and Display

Setting Correction Factor for Feature Value

How to input a correction factor for feature calculation based on measurement tasks.

Feature Calculation and Display

Selecting Channel Connection Formula

Choosing the formula for calculating features based on probe inputs.

Feature Calculation and Display

Selecting Calculation Feature Type

Choosing the type of feature to be calculated (NORMAL, MAX, MIN, etc.).

Master Measurement Procedures

One-Point Master Measurement

Explanation and process for performing a one-point master measurement.

Two-Point Master Measurement

Explanation and process for performing a two-point master measurement.

Master Measurement Configuration

Selecting Master Measurement Type

How to choose between one-point or two-point master measurement.

Entering Nominal Value for One-Point Master

Procedure to input the nominal master value for one-point measurements.

Master Measurement Configuration

Entering Nominal Value for Two-Point Master

Procedure to input nominal master values for two-point measurements.

Performing Master Measurements

Executing One-Point Master Measurement

Step-by-step guide to perform a one-point master measurement.

Executing Two-Point Master Measurement

Step-by-step guide to perform a two-point master measurement.

Setting Tolerances and Limits

Defining Tolerance Limits

How to set upper and lower tolerance limits for workpiece acceptance.

Setting Tolerances and Limits

Defining Warning Limits

How to set warning limits to identify trends before tolerance breaches.

Setting Tolerances and Limits

Configuring Status Lamp Colors

Assigning colors to status lamps for warning and tolerance limit breaches.

Setting Tolerances and Limits

Defining Plausibility Limits

Setting plausibility limits to validate measured value ranges.

Recording Measured Values Configuration

Configuring Filter Parameters

Adjusting filter parameters to reduce interference in measurements.

Recording Measured Values Configuration

Specifying Measuring Sequence Modes

Selecting operating modes like NORMAL or AUTOM. for measurement sequences.

Recording Measured Values Configuration

Understanding Operating Modes

Explains the NORMAL and AUTOM. operating modes for measurements.

Recording Measured Values Configuration

Setting a Start Delay

Configuring a delay before measurement starts to allow oscillations to subside.

Security and Access Control

Activating Password Protection

How to set up a password to protect catalog functions and parameters.

Performing Measurements

Aggregate Measurement Procedure

Step-by-step guide to measure the thickness of a workpiece.

Differential Measurement Procedure

Step-by-step guide to measure the height of a step.

Performing Measurements

Radial Run-Out Measurement

Procedure for measuring radial run-out deviation of a workpiece.

Measured Value Memory Functions

Understanding Measured Value Memories

Explanation of memories for max, min, and mean values during measurements.

Serial Interface Communication

Selecting RS 232 Interface Protocol

Choosing communication protocols (ASCII, M1240, etc.) for serial data transfer.

Serial Interface Communication

Selecting Data Transfer Format

Configuring data bits, stop bits, and parity for serial data transfer.

Selecting Handshake Method

Setting up hardware or software handshake for data flow control.

Serial Interface Communication

Selecting Transfer Rate (Baud Rate)

Setting the data transfer speed (bits per second) for serial communication.

Serial Interface Communication

Selecting Data Transfer Initiation

Choosing manual or automatic initiation for data transfer via serial interface.

Interface Configuration Examples

Printer Data Transfer Configuration

Recommended settings for transferring data to Mahr MSP2 or ASCII printers.

Computer Data Transfer Configuration

Recommended settings for transferring data to a computer via serial interface.

PC Connection and Cabling

Zero-Modem Cable Connection Diagram

Circuit diagram showing how to connect the instrument to a PC using a zero-modem cable.

Parallel (I/O) Interface Usage

Parallel Interface Pin Assignments

Table detailing the pin functions and designations of the 25-pin interface.

Parallel (I/O) Interface Usage

Digital Control Output Functionality

Explains how to use digital outputs and their various operating modes.

Parallel (I/O) Interface Usage

Digital Control Input Functionality

Explains how to assign functions to digital inputs and their operating modes.

Parallel (I/O) Interface Usage

Digital I/O Application Examples

Illustrates connecting to programmable controllers and devices without power supplies.

Parallel (I/O) Interface Usage

Analog Output Feature Selection

How to select which feature is outputted via the analog output.

Parallel (I/O) Interface Usage

Setting Analog Output Sensitivity

Configuring the sensitivity of the analog output signal based on desired voltage.

Error Messages and Troubleshooting

Interpreting Error Codes

Lists common error messages, their causes, and suggested remedies.

Technical Specifications

General Specifications

Provides general data like dimensions, weight, power supply, and protection rating.

Carrier Frequency and Excitation Voltage

Technical details on carrier frequency for different models and excitation voltage.

Measuring Range and Resolution

Specifies the measuring ranges and maximum resolution capabilities.

Response Time and Error Limits

Details response times for outputs and error limits for various displays.

Manufacturer and Support Information

Mahr Contact Information

Details on how to contact Mahr GmbH for support and inquiries.

Product Warranty Terms

Information regarding warranty duration, conditions, and exclusions.