Operating Instructions
3723047
Millimar C 1208 /C 1216 / C 1240
08.11 .2016

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Millimar C 1216 and is the answer not in the manual?

Millimar C 1216 Specifications

General IconGeneral
BrandMillimar
ModelC 1216
CategoryMeasuring Instruments
LanguageEnglish

Summary

Safety Instructions

0 Initial Commissioning

Navigating the Catalog of Functions and Parameters

Explains how to move through the instrument's menu system and settings.

2 Control Elements

Display and Keypad Overview

Identifies and describes the instrument's display, keypad, and status lamps.

Restoring Factory Settings

Procedure to reset the instrument to its original factory default configuration.

3 Performing Basic Settings

4 Positioning the Probe in the Measuring Device (Setup)

5 Aligning Probe Sensitivity

5.1 Calibrating a Measuring Channel

Step-by-step guide to calibrate a single measuring channel for accuracy.

5.2 Aligning Probe Sensitivity (C2 to C1)

Calibrates the sensitivity of a second probe relative to the first for accurate comparison.

6 Inputting Settings for Calculation and Display of a Feature

6.1 Setting the Factor for Correcting Indicated Value

Sets a factor to adjust measurement values based on workpiece or lever ratios.

6.2 Selecting a Channel or Channel Connection (Formula)

Defines the formula used to combine or compare probe inputs for feature calculation.

7 Selecting a Feature

8 Master Measurement

8.1 How to Select the Type of Master Measurement

Guides selection between one-point and two-point master measurement methods.

8.2 Entering Nominal Master Value (One-Point)

Inputting the reference value from a master workpiece for one-point calibration.

8.3 Entering Nominal Master Value (Two-Point)

Inputting reference values from two masters for two-point calibration.

9 Setting Tolerances and Limit Values

9.1 Setting Tolerance Limits

Defines the maximum and minimum acceptable dimensions for a workpiece.

9.2 Setting Warning Limits

Sets alert thresholds to identify trends before tolerance limits are breached.

10 Setting Parameters for Recording Measured Values

10.2 Specifying the Measuring Sequence

Defines the sequence and timing for automated measurements or cycles.

10.4 Operating Mode AUTOM.

Configures the instrument for automated, timed measurement sequences.

11 Password Protection

12 Performing Measurements

12.1 Performing an Aggregate Measurement

Guides measurement of workpiece thickness or combined values.

14 Using the Serial Interface (RS 232)

15 Using the Parallel (I;O) Interface

16 Restoring the Factory Settings

17 Error Messages

18 Technical Data

20 Warranty