SHORTED WATER VALVEThis indicates the water valve is shorted or the wiring to the valve is shorted.
If this condition is detected, the Phase 7 non-coin microprocessor controller (computer) will continue to monitor
the condition for a period of 5 minutes before entering F.S.S. DISABLED Mode. Once the condition is corrected,
the Phase 7 non-coin microprocessor controller (computer) will continue to monitor the condition for 1 minute
before exiting F.S.S. DISABLED Mode.
WATER NOT CONNECTEDThis indicates that there is no water pressure at the water valve. This will
occur if water is not connected to the dryer or if there is low water pressure in the water line coming to the dryer.
This could also be a defective pressure switch or wiring to the pressure switch. If this condition is detected, the
Phase 7 non-coin microprocessor controller (computer) will continue to monitor the condition for a period of 5
minutes before entering F.S.S. DISABLED Mode. Once the condition is corrected, the Phase 7 non-coin
microprocessor controller (computer) will continue to monitor the condition for 1 minute before exiting F.S.S.
DISABLED Mode.
When the F.S.S. is disabled, the user can still start a cycle, however when a cycle is started, the Phase 7
non-coin microprocessor controller (computer) will display the following message, “F.S.S. IS DISABLED.
PRESS ‘START’ TO CONTINUE”. This message will be displayed every time a cycle is started until the
disabling condition has been corrected.