EasyManua.ls Logo

Milnor Phase 7.2.2 - Section VII; Factory Preset Parameters (Programs); Cycle A-F Parameters (Programs) Preset by the Factory; Cycle 0-40 Parameters (Programs) Preset by the Factory

Milnor Phase 7.2.2
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
75
SECTION VII
FACTORY PRESET PARAMETERS (PROGRAMS)
NOTE: To enter Program Mode, press and hold the “STOP/CLEAR” key and the “UP ARROW”
key.
A. CYCLE “A-F” PARAMETERS (PROGRAMS) PRESET BY THE FACTORY
CYCLE A:
SELECT CYCLE TYPE = AUTO, 0:REVERSE MODE = ON, 1:ENTER DRY TEMP = 180°F, 2:ENTER DRYNESS LEVEL =
EXTRA DRY, 3:ENTER CYCLE ADJUSTMENT VALUE = 70, 4:CONTROLLED COOL DOWN = OFF, 5:ENTER COOL DOWN
TIME = 6 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F
CYCLE B:
SELECT CYCLE TYPE = AUTO, 0:REVERSE MODE = ON, 1:ENTER DRY TEMP = 180°F, 2:ENTER DRYNESS LEVEL = DRY,
3:ENTER CYCLE ADJUSTMENT VALUE = 70, 4:CONTROLLED COOL DOWN = OFF, 5:ENTER COOL DOWN TIME = 6
MINUTES, 5:ENTER COOL DOWN TEMP = 80°F
CYCLE C:
SELECT CYCLE TYPE = AUTO, 0:REVERSE MODE = ON, 1:ENTER DRY TEMP = 160°F, 2:ENTER DRYNESS LEVEL = DRY,
3:ENTER CYCLE ADJUSTMENT VALUE = 70, 4:CONTROLLED COOL DOWN = OFF, 5:ENTER COOL DOWN TIME = 4
MINUTES, 5:ENTER COOL DOWN TEMP = 80°F
CYCLE D:
SELECT CYCLE TYPE = MANUAL, 0:REVERSE MODE = ON, ENTER SPIN TIME = 60 SECONDS, ENTER STOP TIME = 5
SECONDS, 1:ENTER DRY TIME = 40 MINUTES, 2:ENTER DRY TEMP = 190°F, 3:CONTROLLED COOL DOWN = OFF,
4:ENTER COOL DOWN TIME = 6 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F, 6:STEAM INJECTION = OFF
CYCLE E:
SELECT CYCLE TYPE = MANUAL, 0:REVERSE MODE = ON, ENTER SPIN TIME = 60 SECONDS, ENTER STOP TIME = 5
SECONDS, 1:ENTER DRY TIME = 30 MINUTES, 2:ENTER DRY TEMP = 180°F, 3:CONTROLLED COOL DOWN = OFF,
4:ENTER COOL DOWN TIME = 4 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F, 6:STEAM INJECTION = OFF
CYCLE F:
SELECT CYCLE TYPE = MANUAL, 0:REVERSE MODE = ON, ENTER SPIN TIME = 60 SECONDS, ENTER STOP TIME = 5
SECONDS, 1:ENTER DRY TIME = 10 MINUTES, 2:ENTER DRY TEMP = 170°F, 3:CONTROLLED COOL DOWN = OFF,
4:ENTER COOL DOWN TIME = 2 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F, 6:STEAM INJECTION = OFF
B. CYCLE “0-40” PARAMETERS (PROGRAMS) PRESET BY THE FACTORY
CYCLE “0-40”:
Manual (Timed) Mode, Reverse, Dry Time = 0, Dry Temp = 100, Cool Down Time = 3 Minutes, Cool Down
Temp = 100, Spin Time = 60, Dwell (Stop) Time = 7.

Table of Contents

Related product manuals