MACSQuant® Instrument
User manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Miltenyi Biotec MACSQuant 16 and is the answer not in the manual?

Summary

Important safety information

Warnings and precautions

Details potential risks and safety guidelines for instrument operation.

Hazard levels

Explains signal words (WARNING, CAUTION) used for safety messages.

Safety symbols

Lists and explains symbols indicating potential hazards to personnel.

General safety instructions

Provides essential guidelines for safe instrument operation and immediate actions in case of issues.

Electricity and fire hazards

Warns about risks from electrical devices, including shock, short circuits, and fire.

Strong magnetic field

Alerts users to risks associated with the instrument's powerful magnet for individuals with implants.

Mechanical hazards

Describes risks from moving parts, including puncturing, crushing, and shearing of body parts.

Optical radiation hazards

Details laser safety, including class, protective housing, and invisible laser radiation warnings.

Chemical and biological hazards

Covers risks associated with handling hazardous materials and necessary precautions.

Introduction

Installation

Components included in the delivery

Lists all items provided with the MACSQuant Instrument package.

Assembly

Guides the user through the physical setup and connection of instrument components.

Install the fluid bottles

Step-by-step instructions for connecting buffer and waste bottles to the instrument.

Operating the instrument

Calibration

Calibrating the sample uptake unit

Guides on calibrating the instrument's sample uptake mechanism.

Calibrating the robotic needle arm

Detailed steps for calibrating the robotic needle arm's position.

Hardware monitor

Maintenance

Decontaminating the instrument

Procedures for decontaminating the instrument after processing hazardous samples.

Troubleshooting

Column leakage

Steps to diagnose and resolve issues related to column leakage.

Syringe pump leakage

Troubleshooting steps for syringe pump leakage problems.

Air bubbles during measurement; no event acquisition

Guidance on resolving issues with air bubbles during measurements.

Excessive debris is present during acquisition

Steps to address excessive debris during sample acquisition.

Touchscreen remains dark

Troubleshooting steps if the instrument's touchscreen is not responding.

Miltenyi Biotec MACSQuant 16 Specifications

General IconGeneral
TypeFlow Cytometer
Number of Parameters16
SoftwareMACSQuantify
Carryover< 0.1 %
Detection TechnologyFluorescence detection
Laser ConfigurationBlue, Red, Violet
Laser Lines488 nm, 405 nm
Lasers3
Power Requirements100–240 VAC, 50–60 Hz