© 2009 MIMAKI ENGINEERING CO.,LTD.
6.5.15 P.2
6.5.15 ID Contact PCB Assy
1
2
3
4
5
6
7
8
4. Remove the relevant cartridge guide.
5. Remove the connector and loosen the screws to take off the ID
contact PCB assy together with ID PCB holder.
6. Remove the ID contact PCB assy.
7. Reverse the disassembly procedure for reassembly.
ID Contact PCB Assy
Loosen
ID Contact PCB Assy
ID PCB Holder
R.1.0
Maintenance Manual > Disassembly and Reassembly > Electrical Parts > ID Contact PCB Assy
Model CJV30/TPC Issued 2008.08.04 Revised F/W ver. 1.00 Remark