EasyManua.ls Logo

MIMAKI CJV30-130 - Skew Check

MIMAKI CJV30-130
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2009 MIMAKI ENGINEERING CO.,LTD.
5.1.21 P.1
1
2
3
4
5
6
7
8
R.1.0
Maintenance Manual > Test Items > Test Function > SKEW CHECK
Model CJV30/TPC Issued 2008.08.04 Revised F/W ver. 1.00 Remark
1.0
Rev.
5.1.21 SKEW CHECK
Function
Skewing of media is checked.
When media is not detected, an OPERATION ERROR (ERROR30) is displayed.
Feed distance is designated to execute feeding.
Feed distance: 1–500 m (unit: 1 m)
During the feeding, remaining of feed distance is displayed with unit of 10 mm.
[END]: Aborts feeding, [ENTER]: Restarts feeding.
Cut jig function
After the Skew check starts (feed distance is not designated), the following operation starts the cut jig function.
[REMOTE] -> [FUNCTION]
The cut jig function repeats media cut feed in feed distance and number of cut times designated.
Number of cut times is displayed in count down during cut.
Feed distance : 10–10000 mm (unit: 10mm, Default 500 mm)
Number of cut times : 1–1000 count (unit: 1count, Default 25 count)