EasyManua.ls Logo

Minebea Intec Signum SIWXSDCP - User Manual

Default Icon
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operating Manual
Minebea Intec Signum
®
3 Ex
Model SIWXSBBP | SIWXSBBS | SIWXSDCP | SIWXSDCS Complete Scales
for Use in Explosive Atmospheres
98648-019-47

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Minebea Intec Signum SIWXSDCP and is the answer not in the manual?

Minebea Intec Signum SIWXSDCP Specifications

General IconGeneral
BrandMinebea Intec
ModelSignum SIWXSDCP
CategoryScales
LanguageEnglish

Summary

Intended Use

Warning and Safety Instructions

Getting Started

Guides the user through the initial setup and unpacking of the scale.

Getting Started

Installing the Display and Control Unit

Details the process of installing the display and control unit on various platforms or separately.

Connecting the Device to AC Power

Explains how to connect the scale to the AC power supply safely and correctly.

Leveling the Weighing Platform

Details the purpose and procedure for leveling the weighing platform for accurate results.

General View of the Equipment

Display and Keypad

Identifies and explains the function of each key and display element on the scale's control panel.

Back Panel

Identifies and describes the connections and ports found on the back of the scale unit.

Operating Concept

Keypad Input

Explains how to use the keypad for inputting data and navigating menus.

Display Modes

Explains the different display modes and symbols used on the scale.

Display in Weighing Mode

Illustrates and details all main display elements and symbols shown during weighing.

Menu Operating Concept

Details the concept of operating the scale via its menu system.

Error Messages

Data Output

Printer

Explains connecting a printer for printouts and configuring print formats.

Digital Input;Output Interface + Optional I;O

Details support for digital I/O for checkweighing and classification applications.

Communication Interface

Explains parameter configuration for the SBI interface.

Saving Data

Configuration

Language Settings

Details how to select and change the display language for the scale.

Protecting Setup With a User Password

Guides on how to assign a password to protect setup parameters from unauthorized changes.

Operating Menu Overview

Provides a structured overview of the device's menu levels and their corresponding functions.

Operating Menu

Application programs

Lists and describes the available application programs for scale configuration.

Neutral measurement

Details parameters for the neutral measurement application, including initialization and resolution settings.

Averaging (animal weighing)

Lists parameters for the averaging application, covering start modes, animal activity, and printout settings.

Weighing in percent

Outlines parameters for the weighing in percent application, including minimum load and display settings.

Checkweighing

Details checkweighing parameters like range, control outputs, activation, parameter input, and automatic printing.

Setup

Device Parameters

Covers parameters related to the device itself, such as keypad and display settings.

Calibration and Adjustment

Covers the process and sequences for calibrating and adjusting the scale.

Data Interface

Configuring the Data Interface as a COM Port ( datprot, when com1 is not RS485 )

Explains how to configure the interface as a COM port.

Data Input Format (Commands)

Lists commands and their meanings for controlling the scale via the interface.

Data Output Format

Details the format of data output for print jobs, including character counts and headers.

Error Message:

Lists common error messages and their meanings.

Configuring the Data Interface as a Printer Port (printer, when com1 is not RS485)

Explains how to connect and configure the scale's interface as a printer port.

Automatic Data Output (SBI)

Explains how to configure automatic printing of weight readouts.

GMP-compliant Printouts

Details the settings for GMP-compliant printouts, including headers and footers.

Care and Maintenance

Cleaning

Provides instructions for cleaning the scale safely and effectively.

Safety Inspection

Outlines conditions requiring safety inspections and how to proceed.

Overview of Accessories

Re-verification in Germany

Explains the process and requirements for re-verification of scales in Germany.

Subsequent Verifications within European Countries

Explains procedures for subsequent verifications in European countries.

Certificates

Installation instructions

Provides instructions for safe installation of the equipment.

Special conditions for safe use

Lists specific conditions required for safe operation.

Essential Health and Safety Requirements

Confirms compliance with essential health and safety requirements.

FM;CSA Certificate

13. Specific Conditions of Use:

Lists specific conditions required for safe use.

Control Drawing

Notes

1) In the USA: The installation must be in accordance with the National Electrical Code...

USA installation requirements according to National Electrical Code.

In Canada: The installation must be in accordance with the Canadian Electrical Code...

Canada installation requirements according to Canadian Electrical Code.

7) The cable must be protected against damage.

Emphasizes the need to protect cables from damage.

11) The cable to the T-Connector must be protected against damage.

Stresses the importance of protecting the T-Connector cable.

Data output options

Important note!

Provides important notes regarding maximum voltage and Zener voltage.

Power supply options

Safety Instruction

1) Install the equipment in compliance with applicable laws, rules and regulations, ordinances and standards.

General instruction to install equipment according to applicable laws and standards.

3) The equipment shall be installed in such a way that it is protected against the entry of solid foreign objects or water...

Specifies installation requirements for protecting the apparatus from foreign objects and water.

5) Exposure to UV radiation is not allowed!

Warns against exposure to UV radiation.

6) The connecting cable of the display unit must be prevented against damage and stress caused by strain.

Instructs to prevent damage and strain to the display unit's connecting cable.

7) Prior to opening the equipment, disconnect the power supply or make sure that there is no potentially explosive atmosphere...

Safety instruction for opening the equipment, requiring power disconnection and checking for explosive atmospheres.

8) The data cable connected to the equipment is considered as intrinsically safe circuit.

States that the data cable is considered an intrinsically safe circuit.

10) All metal parts must be electrically connected to the terminal for the equipotential bonding conductor (PA).

Mandates electrical connection of all metal parts to the equipotential bonding conductor.

11) Avoid generating static electricity. Use only a damp cloth to wipe down the equipment.

Advises on preventing static electricity and proper cleaning methods.

12) Keep chemicals and other agents, which can corrode the housing seals...

Warns to keep corrosive chemicals away from the equipment.

13) Use equipment only in the temperature ranges indicated. Avoid exposing the equipment to heat.

Stresses operating within specified temperature ranges and avoiding heat exposure.

15) Check the EX approval marking (particularly the group for gases;dusts and temperature class;code)...

Requires checking EX approval markings before operating in hazardous areas.

16) At reasonable intervals, have your equipment installation checked...

Recommends periodic safety checks by certified technicians.

19) Modifications, including those to be carried out by Sartorius employees...

Permits modifications only with express written authorization.

20) If an IP6 x housing has been opened, replace the gaskit and close the housing...

Provides instructions for re-sealing IP6x housings after opening.

General Password

Appendix: General Password

Explains how to enter and set the general access password for the setup menu.

Enter password

Details the process of entering the password using the keypad.

Confirm the password

Explains how to confirm the entered password.

Save settings and exit menu

Explains how to save settings and exit the menu.

Related product manuals