164
Item Function No. Number Contents
Target of brand changeover
70 51
0: Changeover by function
1: Changeover by external control input
2: Changeover by communication
Brand number
70 52
0 ~ 7
Setting F key operation
70 55
0 : OFF, 1 : Print Input, 2: Hold Input,
3 : Batch start, 4 : Emergency stop, 5 : Zero clear,
6 : Tare clear, 7 : Accumulation clear,
8 : Measurement comparison,
9 : Forced batch finish
External control input
INPUT1 operation setting
70 60 0: OFF
1: key operation
2: key operation
3: key operation
4: key operation
5: key operation
6: key operation
7: key operation
8: key operation
9: Zero clear
10: Tare clear
11: Flow start
12: Discharge start
13: Flow/Discharge changeover
ON: Discharge, OFF: Flow
14: Clear the last accumulated data
15: Accumulation clear
16: Error cancellation
17: Print command
18: Hold
19: Emergency stop
20: Manual free fall compensation
21: Net display
22: Forced batch finish
23: Forced discharge finish
24: Accumulation clear for all brands
25: Brand No. 1
26: Brand No. 2
27: Brand No. 4
External control input
INPUT2 operation setting
70 61
It is optional as well as F-60
External control input
INPUT3 operation setting
70 62
It is optional as well as F-60
External control input
INPUT4 operation setting
70 63
It is optional as well as F-60
External control input
INPUT5 operation setting
70 64
It is optional as well as F-60
External control input
INPUT6 operation setting
70 65
It is optional as well as F-60
Please change [7*] of above mentioned command to [8*] about the command at the time of
writing.