52
Item Function No. Setting value Contents
19 Emergency stop
20 Manual free fall compensation
21 Net display
22 Forced batch finish
23 Forced discharge finish
24 Accumulation clear for all brands
25 Brand No. 1
26 Brand No. 2
27 Brand No. 4
External control input INPUT2
operation setting
F-61 It is optional as well as F-60
External control input INPUT3
operation setting
F-62 It is optional as well as F-60
External control input INPUT4
operation setting
F-63 It is optional as well as F-60
External control input INPUT5
operation setting
F-64 It is optional as well as F-60
External control input INPUT6
operation setting
F-65 It is optional as well as F-60
External control input INPUT7
operation setting
F-66 It is optional as well as F-60
External control input INPUT8
operation setting
F-67 It is optional as well as F-60
External control input INPUT9
operation setting
F-68 It is optional as well as F-60
External control output
OUTPUT1 operation setting
F-70
00
OFF
01 Stable
02 During canceling the Tare weight
03 Display of Gross
04 Display of Net
05 Zero
06 During the hold
07 Error
08 Abnormal weight
09 Measuring sequence error
10 Z-Band
11 OK (S0)
12 F flow (S1)
13 M flow (S2)
14 D flow (S3)
15 Over (S4)
16 Under
17 Full
18 During weighing
19 Finish weighing
20 Discharge (between the discharge gate)
21 Finish Discharge
(between the discharge gate)
22 RUN
Has been set as default