EasyManua.ls Logo

Minebea CSD-903-EX - Page 74

Minebea CSD-903-EX
226 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
58
8-8. Print command
Execute the setting of print operation of manual and automatic, manual printing operation is used
when the print operation is executed by the method either setting the F key to print or using the
external control I/O.
Automatic print operation is used to print out automatically at every time when load on a weighing
section is measured by using a 2-wires method serial interface, BCD output interface or RS-422/485
interface.
8-8-1. Print operation status
The print operation status is selected by function F-16.
Setting range: 00-11
10
0
digit: manual print operation effective only in the stable.
[0]: Effective only in the stable. [1]: Always effective
10
1
digit: Automatic print operation.
[0]: Turn off the automatic printing. [1]: Automatic printing in the stable.
[00] is selected as default. Print by ‘Print input’ with setting or external control I/O.
8-9. Hold
This function retains the various data of a load display value, a comparison result, a CC-link
interface and a serial interface while measuring.
The hold signal can input by setting the into hold or by using the external control I/O.
8-9-1. Hold operation
Select the hold operation status by function F-17.
Hold operation status is selectable from [Synchronizing with Hold] or [Synchronizing with Batch Finish]
Default is set to [Synchronizing with Hold].
8-9-2. Hold target
(1) Hold of load display value
Whether valid or invalid of holding operation of load display value is selected by the setting of 10
0
digit
of F-18.
Default is set to [Valid].
The load display section changes into the error display of [OL] or [OVF] when [OL] or [OVF] error
occurs while the holding operation of load display value.
(2) Hold of comparison result
Whether valid or invalid of holding operation of comparison result is selected by the setting of 10
1
digit
of F-18. Default is set to [Invalid].
The holding targets of the simple comparison mode and the sequential mode are the signals of [Full
Flow], [Medium Flow], [Dribble Flow], [Over], [OK], [Under], [Full] and [Near Zero].
The holding targets of the 4-steps comparator mode are the signals of [S1], [S2], [S3], [S4], [Full] and
[Near Zero].
The condition data of a condition display, I/O output, Standard RS-485, RS-232C, RS-422/485 and
CC-link corresponding to the holding target of comparison result is also held during the holding
operation of comparative result.