EasyManua.ls Logo

Minelab EQUINOX 900 - Iron Bias (Advanced Setting); Adjust the Iron Bias

Minelab EQUINOX 900
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
CONTENTS
Iron Bias (Advanced Setting)
Iron Bias allows the detector to correctly
classify large or complex ferrous targets (e�g�
rusty nails or crown bottle caps) as ferrous so
that they are more easily rejected�
Iron Bias is only available when the operating frequency is
set to Multi�
Iron Bias adjustment is local; only the current Search Mode
Profile is affected by changes to this setting�
EQUINOX 900 Iron Bias ranges from 0 to 9�
EQUINOX 700 Iron Bias ranges from 0 to 3�
Note: For EQUINOX 600 and 800 users, be aware that Iron
Bias settings are not identically configured and named in
the 700 and 900 models�
HOW IRON BIAS WORKS
All ferrous targets produce a combination of ferrous and
non-ferrous responses� Large ferrous targets can present
an even stronger non-ferrous response� Adjacent ferrous
and non-ferrous targets can produce a similar response�
CHOOSING AN IRON BIAS SETTING
Set the Iron Bias Setting to suit the type of targets you
want to detect or ignore�
Lower Iron Bias Settings
A lower Iron Bias setting (0–4 on EQUINOX 900, or 0–2
on EQUINOX 700) is recommended In areas where you do
not want to miss any non-ferrous targets amongst iron
trash, however more ferrous targets will be detected and
misidentified as desirable non-ferrous targets�
When using a lower Iron Bias setting, detecting in
All Metal Mode is recommended to avoid missing any
desirable targets�
Higher Iron Bias Settings
A higher Iron Bias setting (5–9 on EQUINOX 900, or 3 on
EQUINOX 700) is recommended in environments with dense
iron trash, or for rejecting crown bottle caps�
When using a higher Iron Bias setting, detecting using a
ferrous-masking discrimination pattern is recommended to
mask as many ferrous detections as possible�
ADJUST THE IRON BIAS
The Iron Bias Setting provides tone and Target ID response
adjustment for a wide range of ferrous targets
1. Press the Settings button to navigate to the Recovery
Speed setting�
2. Long-press (2 seconds) the Settings button to select
the Iron Bias Advanced Setting� 'FE' will appear on the
Frequency Display
(2 Seconds)
3. Use the Minus (–) and Plus (+) buttons to adjust the
Iron Bias setting� Adjustments are automatically saved�
EQUINOX 700/900 Iron Bias Setting Equivalents
The following shows the equivalent Iron Bias settings
between the two models� EQUINOX 700 has fewer
adjustment increments than the EQUINOX 900�
EQUINOX 900 0 1 2 3 4 5 6 7 8 9
EQUINOX 700 0 1 2 3

Other manuals for Minelab EQUINOX 900

Related product manuals